Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Category: Water
Created on: 18 May 2013

Features: Compact 1/16 DIN size fits into standard industry panel cutouts. Microprocessor based for fast, reliable and accurate measurements. Easy to calibrate by one keyboard. Degree ℃/℉ are switchable. The large backlight LCD display pH or Conductivity and Temperature simultaneously. Optional NEMA-4X gasketed lens cover fits over front bezel of controller-made of watertight corrosion resistant ABS plastic. Specifications:     pH ORP Temp Conductivity TDS Salt Temp Range -2~16.00 ±1000 mV 0~90.0 ℃ 0~2000μS 2.00~20.00 mS 0-1300 ppm 1.30~13.00 ppt 0~1000 ppm 1.00~10.00 ppt 0~90 ℃ Accuracy ±0.01+1 digit ±2+1 digit ±0.2+1 digit ±2% FS ±0.2+1 digit Resolution 0.01 pH 1 mV 0.1 ℃ 1 μS/0.01 mS 1 ppm/0.01 ppt 1 ppm/0.01 ppt   Power 9V DC  (AC adaptor) Panel cutout 1/16 DIN/1.77 x 1.77"(45 x 45 mm), Depth 4.2"(106 mm) Weight 70 g without NEMA-4X   Accessories for complete kit: pH, ORP electrode or Conductivity cell Temperature probe Standard solution DC/AC adaptor

Category: Water
Created on: 18 May 2013

Features: Compact 1/16 DIN size fits into standard industry panel cutouts. Microprocessor based for fast, reliable and accurate measurements. Easy to calibrate by one keyboard. Degree ℃/℉ are switchable. The large backlight LCD display pH or Conductivity and Temperature simultaneously. Optional NEMA-4X gasketed lens cover fits over front bezel of controller-made of watertight corrosion resistant ABS plastic. Specifications:     pH ORP Temp Conductivity TDS Salt Temp Range -2~16.00 ±1000 mV 0~90.0 ℃ 0~2000μS 2.00~20.00 mS 0-1300 ppm 1.30~13.00 ppt 0~1000 ppm 1.00~10.00 ppt 0~90 ℃ Accuracy ±0.01+1 digit ±2+1 digit ±0.2+1 digit ±2% FS ±0.2+1 digit Resolution 0.01 pH 1 mV 0.1 ℃ 1 μS/0.01 mS 1 ppm/0.01 ppt 1 ppm/0.01 ppt   Power 9V DC  (AC adaptor) Panel cutout 1/16 DIN/1.77 x 1.77"(45 x 45 mm), Depth 4.2"(106 mm) Weight 70 g without NEMA-4X   Accessories for complete kit: pH, ORP electrode or Conductivity cell Temperature probe Standard solution DC/AC adaptor

Category: Water
Created on: 18 May 2013

  90 degree scattered light method   Turbidity Checker TSC-10(E) uses a method of 90 degree scattered light as the measuring principle of the world common standard. Built-in wiper cleaning system   The built-in wiper cleaning system certainly keeps lenses clean. Sapphire glass of the optical windows   The optical windows are made of hard-to-scratch sapphire glass. It enables to scrub the window surface to maintain the Turbidity Checker. Compact design   The compact design makes it possible to install easily. Turbidity Checker TSC-10(E) got the Pattern Approval Certificate of the measuring instruments of the People's Republic of China. Model No. TSC-10(E) Measuring range 0.00-500.0 (NTU/FNU) Power supply voltage AC100-240V±10% 50/60Hz Power consumption Nomal:15VA or less, During cleaning:22VA max. Display resoltion 0.01(0.00-19.99), 0.1(20.0-500.0)NTU/FNU Output Signal Output (analog 4-20mA, resistance load of 300 max.) Self-checking Relay Output (non-voltage C-contact capacity 240VAC,...

Category: Water
Created on: 18 May 2013

    This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .   Analogue output (4-20mA) allows you to use this checker with various equipments. Wiper for easy maintenance   Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month. Compact size   Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit. High durability   Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass. Turbidity Checker TC-100/500/3000 SS Checker TCS-1000 The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response...

Category: Water
Created on: 18 May 2013

    Easy to measure turbidity.   You can easily measure the water turbidity anywhere with this portable sensor because it cannot be affected by external disturbance light. Unnecessary to draw the water.   You just put the probe into the water to measure turbidity. You can avoid the hassle of drawing the water. High durability   Controller Unit: Waterproof IP67. Anti-bacterial metrical is used. Sensor Unit: Durable SUS316L is used. Optical window is made of sapphire glass. It is equipped with a rubber to absorb the impact from wear and shock.   Model No. TD-M500 Measuring Technique Attenuated Light Method Measuring Range 0.0-500FTU Display Resolution 0.1FTU (0.0-99.9), 1FTU (100-500) Calibration Distilled Water or Air Calibration Correction Single or Double Point Correction Power Requirements 9V Layer-built Alkaline Dry Battery (6LR61) Battery Life Approx. 8000 measurements Water Temperature 0 to 40℃ (32 to 104°F) Operating...

Category: Water
Created on: 18 May 2013

  The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response time, alarm level setting and so on. You can control the turbidity/SS utilizing its functions fully. Power Supply 50/60Hz Signal output Alarm output Degree of protection Jet-proof type (IP65) Transmitter forSuspended Solids Checker

Category: Water
Created on: 18 May 2013

    This checker can be used for continuous monitoring of the water turbidity (TC-100/500/3000) and suspended solids (TCS-1000) .   Analogue output (4-20mA) allows you to use this checker with various equipments. Wiper for easy maintenance   Original wiper certainly keeps lenses clean. Stain of lenses need to be checked only once a month. Compact size   Simple cylindrical design in compact size approx ¢32 x 170mm (1.26 x 6.69 inch). Requires small space to set up the unit. High durability   Durable stainless steel has been used for the sensor casing. Stainless steel = 18-15-2.5 Cr-Ni-Mo low C stainless steel Lenses are made of hard-to-scratch sapphire glass. Turbidity Checker TC-100/500/3000 SS Checker TCS-1000 The transmitter is also available to use in combination with the Turbidity Checker / SS Checker.   As well as the turbidity/SS indication, this transmitter can indicate signal output response...

Category: Water
Created on: 18 May 2013

  TS-Mx(E) (System model) Wide range of 50,000 mg/L measurement as maximum   The wide range measurement can be possible to monitor MLSS concentration in the aeration basin. Easy installation, Simple operation   For user-friendly, TS-Mx(E) is designed as a concept of easy installation and simple operation. Built-in wiper cleaning system   The built-in wiper cleaning system certainly keeps lense clean. Sapphire glass for scratch proof   The optical windows are made of hard-to scratch sapphire glass. It enables to scrub the window surface to matintain the Sensor. TS-MxS-A (Analog output model) 4-20mA analog output   4-20mA analog output is provided from TS-MxS-A Sensor. It is possible to connect to the system such as PLC directly. Wide range of 50,000 mg/L measurement as maximum   The wide range measurement can be possible to monitor MLSS concentration in the aeration basin. Built-in wiper cleaning system   The built-in wiper cleaning system certainly...