KYORITSU MALAYSIA

Sub Categories

  • Filter
Created on: 19 May 2013

 a neon HV potential indicator suitable for use on earthed neutral systems up to 11kV.

Created on: 12 February 2014

Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Category: Recorders
Created on: 23 October 2014

CENTER 340 is a temperature dataloggers. Even though these units are focused on data collecting, we placed a LCD to show the operator on site information. In case of dark environment, it is also equipped with backlit display. Both units feature a real time clock inside so that the event are captured with time stamps. The recording memory can hold up to 64000 records which can provide high resolution test results.   With waterproof hosing, the temperature datalogger 340 has a lot of applications such as environmental monitoring, food transportation process monitoring, or air condition monitoring, etc. The data is downloaded through IR photo interface so the connector is not damaged by water.

DC, 0.5 Hz To 1 MHz, 6-Channel 3-Phase 4-Wire Power Meter with Direct and Clamp Sensor Input Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3193-10 is a 6-channel power meter for testing any type of circuit ranging from single-phase lines to three-phase four-wire lines. Based on the voltage, current, and active power measurements, the power meter calculates and displays reactive power, apparent power, power factor, phase angle, and efficiency. It also provides a wide range of measurement functions including frequency measurement function, peak measurement function, current integration, active power integration, analog outputs, monitor outputs, and optional harmonic analysis/flicker functionality. Note: Main unit 3193-10 cannot operate alone - please purchase an input unit Model 9600 to 9605 for factory installation prior to shipment. All subsequent input unit replacements or expansions must be conducted at HIOKI for an additional service charge.

Created on: 20 October 2014

Features * 150/100/70MHz Bandwidths* 1GSa/s Real-Time Sample Rates Maximum, 25GSa/s Equivalent-Time* 2Mega Points Record Length* 2mV~10V Vertical Scale* 1ns~50s Horizontal Range* Up to 27 Automatic Measurements* 5.7" TFT LCD Display* USB Host and Device Interface Supported* Go/NoGo Function* Data Logger* Limited Lifetime Warranty

Created on: 23 October 2014

Features:  Measurement range: -50 to 200°C; -58 to 392°F Tolerances: ±2.2°C (±3.9°F)

Created on: 31 January 2014

150°C ½ AA High Temperature Battery

Created on: 20 October 2014

Features * 100/70/50 MHz Bandwidth with 2 Input Channels* 250MSa/s Real-Time and 25GSa/s Equivalent-Time Sampling * 4k Memory Length per Channel * Peak Detect as Fast as 10ns * Save/Recall of 15 Front Panel Settings & Waveforms * 5.7" TFT Color Display * 19 Auto Measurements * Arithmetic Operators - Add, Subtract, FFT * USB Port for PC Connection* Data Logger * Limited Lifetime Warranty