Lowest Price

TES0029 3600 3-PHASE POWER ANALYZER COMPLETE WITH 3 X 1000A CLAMPS AND SOFTWARE

 

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (512KB Memory, 20,000 sets)
  • Programmable Trigger - Points and Start / Stop Time.
  • RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.
   
   
   

THREE PHASE POWER ANALYZER

Order number: TES0029


  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (512KB Memory, 20,000 sets)
  • Programmable Trigger - Points and Start / Stop Time.
  • RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.

 

Voltage Measurement (V)

Ranges

Method

Accuracy

Input impedance

600.0V

True RMS

± 0.5%rdg ± 10dgts (>30V)

2M Ω

Current Measurement (A)

Ranges

Method

Accuracy

250A 、 500A 、 1000A

True RMS

± 0.5%rdg ± 10dgts + clamp on sensor specifications

Active Power Measurement (KW)

Ranges

Accuracy

Effect of power factor

600.0KW

± 0.5%rdg ± 10dgts + clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)

Ranges

Accuracy

Effect of power factor

600.0KVAR

± 0.5%rdg ± 10dgts + clamp on sensor specifications

± 0.1%rdg

Apparent Power Measurement (KVA)

Ranges

Accuracy

600.0KVA

± 0.5%rdg ± 10dgts + clamp on sensor specifications

Power Integration Measurement

Power Integration

Resolution

Accuracy

0.0KWh to 9999MWh

0.1KWh

± 0.5%rdg ± 10dgts + clamp on sensor specifications

0.0Kvarh to 9999Mvarh

0.1Kvarh

0.0KVAh to 9999MVAh

0.1KVAh

Power Factor Measurement

Ranges

Accuracy

Polarity display

-1.000(lead) to 0.000 to + 1.000 (lag)

± 1dgt for each calculation from measured values

When the current lags the voltage unsigned ; when the current leads the voltage : "-".

Frequency Measurement

Ranges

Measurement source

Accuracy

40Hz to 100Hz

Voltage U1

± 0.5%rdg ± 1dgt

General Specifications

Size

235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)

Operating Temperature and Humidity

0 ℃ to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing

Storage Temperature and Humidity

- 10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing

Accessories

1) Instruction manual
2) Software CD Rom / Optical RS-232 interface
3) Deluxe carrying case
4) Battery (“AA” 1.5V x 8pcs )
5) AC adaptor (110V -> 12V ; 220V -> 12V)
6) 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm)
7) 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)

AddThis Social Bookmark Button