From Taiwan

PRO0030 6830 Power Analyser From Taiwan

alt


alt
alt
  • Available with 100A, 1000A or 3000A clamps (3 pcs)
  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS Value (V 123 and L 123 )
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)
  • Energy (WH, KWH, KVARH, PFH)
  • Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
  • Display of 35 Parameters in One Screen(3P4W)
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in W, KW, MW) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in One Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples/Period)
  • Analysis of Total Harmonic Distortion (%THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
  • 3 Phase Voltage Unbalance Ratio (VUR)
  • 3 Phase Voltage Unbalance Factor (d0%, d2%)
  • Calculated Unbalance Current through Neutral Line (In)
  • Optical isolated USB Interface
  • Built-in Timer and Calendar for Data Logging
  • Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
  • 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)

http://tes.com.tw/image/featuree.gif

http://tes.com.tw/pro-images/6800.gif



  • Analysis for 3P4W, 3P3W, 1P2W, 1P3W
  • True RMS Value (V 123 and L 123 )
  • Active Power (W, KW, MW, GW)
  • Apparent and Reactive Power (KVA, KVAR)
  • Power Factor (PF), Phase Angle (Φ)
  • Energy (WH, KWH, KVARH, PFH)
  • Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
  • Display of 35 Parameters in One Screen(3P4W)
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • Display of Overlapped Voltage and Current Waveform
  • 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
  • Output of Waveform, Power Parameters and Harmonics at Command
  • Large Dot Matrix LCD Display with Backlight
  • Average Demand (AD in W, KW, MW)
  • Maximum Demand (MD in W, KW, MW) with Programmable Period
  • Harmonic Analysis to the 99th Order
  • Display of 50 Harmonics in One Screen with Waveform
  • Display of Waveform with Peak Values (1024 Samples/Period)
  • Analysis of Total Harmonic Distortion (%THD-F)
  • Graphic Phasor Diagram with 3 Phase System Parameters
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
  • 3 Phase Voltage Unbalance Ratio (VUR)
  • 3 Phase Voltage Unbalance Factor (d0%, d2%)
  • Calculated Unbalance Current through Neutral Line (In)
  • Optical isolated USB Interface
  • Built-in Timer and Calendar for Data Logging
  • Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
  • 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)

http://tes.com.tw/image/spee.gif

* Please refer to users manual for more detailed and up-to-date description of specification

AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)

Range

Resolution

Accuracy of Readings

6800+6801

6800+6802

6800+3007

5.0 – 999.9W

0.1W

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

1.000 – 9.999 KW

0.001 KW

±1% ± 8 dgts

±1% ± 8 dgts

±1% of VA Range ±8dgts

10.00 – 99.99 KW

0.01 KW

±1% ± 8 dgts

±1% ± 8 dgts

±1% of VA Range ±8dgts

100.0 – 999.9 KW

0.1 KW

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

1000 – 9999 KW

1 KW

±1% ± 8dgts

±1% ± 8dgts

±1% of VA Range ±8dgts

0.000 – 9.999MW

0.001MW

–

±1% ± 8 dgts

±1% of VA Range ±8dgts

AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor

Range

Resolution

Accuracy of Readings

6800+6801
(Overload Protection AC200A)

0.050 – 9.999A

0.001A

±0.5% ± 5dgts

10.00 – 60.00A

0.01A

±0.5% ± 5dgts

60.00 – 99.99A

0.01A

±1.0% ± 5dgts

6800+6802
(Overload Protection AC2000A)

0.04 – 10.00A

0.01A

–

0.4A – 100.0A

0.1A

±0.5% ± 5dgts

4.0 – 1000.0A

1A

±0.5% ± 5dgts

6800+ 3007
(Overload Protection AC3500A)

4 – 300A

0.1A

±1% of Range ±5dgts

300.0 – 999.9A

0.1A

±1% of Range ±5dgts

1000 – 3000A

1A

±1% of Range ±5dgts

AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor

Range

Resolution

Accuracy of Readings

Range

Resolution

Accuracy of Readings

4.0V – 500.0 (Phase to Neutral)

0.1V

± 0.5% ± 5dgts

4.0V –600.0V (Phase to phase)

0.1V

± 0.5% ± 5dgts

Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V)

Range

In Percentage

In Magnitude

Resolution

Accuracy of readings

Resolution

Accuracy of readings

1 – 20 th

0.1%

±2%

0.1 V

±2% ±0.5V

21 – 49 th

4% of reading ±2.0%

4% of reading ±0.5A

50 – 99 th

6% of reading ±2.0%

6% of reading ±0.5A

Harmonics of AC Current in % and in Magnitude
Model 6800+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range)

Range

In Percentage

In magnitude

Resolution

Accuracy of reading

Resolution

Accuracy of reading

1 – 10 th

0.1%

±0.2 of reading ±1%

0.1mA / 0.1A

±0.2% of reading ±7dgts

11 – 20 th

±2% of reading ±1%

±2% of reading ±7dgts

2 1 – 50 th (A range)

±5% of reading ±1%

±5% of reading ±7dgts

2 1 – 50 th (mA range)

±10% of reading ±1%

±10% of reading ±7dgts

5 1 – 99 th

±35% of reading ±1%

±35% of reading ±7dgts

Model 6800+6802(1000A);6800+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A)

Range

In Percentage

In Magnitude

Resolution

Accuracy of reading

Resolution

Accuracy of reading

1 – 20 th

0.1%

±2%

0.1A(6802) / 0.3A(3007)

±2% of reading ±0.4A/0.6A

21 – 49 th

4% of reading ±2.0%

±4% of reading ± 0.4A/0.6A

50 – 99 th

6% of reading ±2.0%

±6% of reading ± 0.4A/0.6A

Total Harmonic Distortion

Range

Resolution

Accuracy(6801)

Accuracy(6802)

Accuracy(3007)

0.0 – 20%

0.1%

±1%

±2%

±2%

20 – 100%

0.1%

±3% of reading ±5%

±6% of reading ±1%

±6% of Range ±1%

100 – 999.9%

0.1%

±10% of reading ±10%

±10% of reading ±1%

±10% of Range ±1%

Peak Value of Ac Voltage or AC Current ,VT=1

Range

Sampling Time

Accuracy of reading

50Hz

39 μS

±5% ±30digits

60Hz

33 μS

±5% ±30 digits

Crest Factor (C.F.) of ACV or ACA ,VT=1

Range

Resolution

Accuracy of reading

1.00 – 99.99

0.01

±5% ±30digits

Frequency in AUTO mode

Range

Resolution

Accuracy of reading

45 – 65Hz

0.1Hz

0.1Hz

Power Factor (PF)

Range

Resolution

Accuracy of reading

0.00 – 1.00

0.01

± 0.04

Phase Angle (Φ)

Range

Resolution

Accuracy of reading

-180 。 to 180 。

0.1 。

± 1 。

Conductor Size (6801)

30mm (approx.)

Conductor Size (6802)

55mm(approx.), 64 X 24mm(Bus Bar)

Battery Type

1.5V SUM-3 x 8

Display

Dot Matrix LCD with backlight

Power Consumption

140mA (approx.)

External DC Input

DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection)

LCD update rate

1 times / sec

No. Of Samples/Period

1024

Operating Humidity

< 85% relative

Operating Temperature

-10°C to 50°C

Storage Humidity

< 75% relative

Storage Temperature

- 20°C to 60°C

Weight(6800)

1160g

Weight(6801)

200g

Weight(6802)

600g

Dimension(6800)

257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H)

Dimension(6801)

210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H)

Dimension(6802)

244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H)

Accessories

Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8

AddThis Social Bookmark Button

Additional information