General Info

Flue gas analyser

"Yes! You will find the best deal here, I promise. My name is STEVEN.

I have come out with the following information which,I believe, will help

you to get the correct gas analyser."

 


 

Firstly,

Why do you need a flue gas analyser?

Download flue gas analyser guide here.

Secondly,

Give our combustion specialist who is also our sales manager, Steven, a call

at +6017-3455775.

"I promise to make sure you get the most suitable flue gas analyser based on my knowledge on the products, my experience with your industry and more importantly, my passion to assist our customer."

 

FAQ (Answered by Steven)

 

 

What are the features of your flue gas analyser?


Where is your flue gas analyser from?

All our flue gas analysers are made in Germany including the base unit, gas modules, flue gas probe, carrying case.

Who is using our flue gas analysers?

Shell, Petronas, PetroPlus, Exxon Mobil and many others.

How much does a combustion analyser normally costs?

Range from RM 3000 to RM50000 or USD 882 to USD 15151 depending on your requirement.

Does your flue gas analyser comes with warranty?

Of course. The brand we carry has been around in the industry for over 50 years.

I WILL GET YOU THE MOST SUITABLE ANALYSER AT THE

LOWEST COST POSSIBLE BASED ON YOUR REQUIREMENTS.

REMEMBER TO GIVE US A TRY!

 

 

http://www.powrtechsolutions.com/images/testo.jpg

KKInstruments represents Testo, Inc., who is a major worlwide supplier of portable flue gas analyzers.

Allow us to bring one to you and demonstrate its use on your furnace.
KKInstruments has been selling portable flue gas analyzers for 5 years. Combined with our knowledge of combustion applications in boilers and processes, we can provide valuable insight to the application and operation of this kind of equipment.
Portable flue gas analyzers are an inexpensive way to get very accurate flue gas analysis if used properly. They utilize fuel cell sensors, remove moisture from the samples and take into account sample flow, oxygen corrections and various ways of reading emissions based on the process to which it is being applied.
As a result of these measuring methods, it is important to pay attention to certain features of portable flue gas analyzers:

  • They utilize fuel cells which, like a battery, only last a certain time including shelf life, then must be replaced and recalibrated. Those cells are slowly, steadily declining their output linearly, and must be re-zeroed before each use.
  • They must be recalibrated for a new zero every time they are used due to the above mentioned deteriorating life, and that zero calibration must be done at ambient conditions where air is clear of CO, etc., Do not zero near the flue gas measurement area.
  • Because they measure flue gas after moisture is removed, they are a “dry” analyzer. When compared to a “wet” analyzer, such as a zirconium oxide insitu continuous oxygen analyzer which measures oxygen in flue gas without removing moisture, there will be a 1 to 2 % difference in Oxygen reading depending on how much moisture is present.

http://www.powrtechsolutions.com/images/testo_1.jpg

Testo Model 335 Portable Flue Gas Analyzer
This hand held analyzer acomodates up to three cells, and comes with the following standard features:
O2, CO, NO cells
Calculation of NOx, CO2, Efficiency, excess air, dew point.
Auto zero calibration, ambient and stack temperature.
Sampling pump drawing up to 80 in wc.
Calculation based on 18 standard fuels.
Moisture collection traps and filters.
Diagnostics.
 


Options:

Other Cell Options:

Probes & Hoses:

Printer
Battery and Charger
Carrying case
Emissions software
Draft measurement

CO low 0-500 ppm
NO low 0-300 ppm
NO2 0-500 ppm
SO2 0-5000 ppm
Dilution 2X

Standard is 12 “ probe, 7’ hose.
Options are:
28 “ probe
9 ‘ hose
Hi Temp
Pitot tube

Testo offers their 335 in affordable kit form to provide frequently requested combinations of features at very good prices.


 Feature:

#1 Basic

#2 Standard

#3 NO

#4 Engine

 Oxygen 0 – 25%

X

X

X

X

 CO 0 – 10,000 ppm

 

X

X

X

 NO 0 – 3000 ppm

 

 

X

X

 Dilution X2

 

 

 

X

 Printer

 

 

X

X

 12 “ Probe & 7’ Hose

X

X

X

 

 Power Supply and Battery

X

X

X

X

 Extra battery and charger

 

X

X

X

 Filters (10) and paper (6)

X

X

X

X

 Case

X

X

X

X

 

 

 

 

 

         

 Options and upgrades can be added to kits.

Testo Model 350 Portable Flue Gas Analyzer
This analyzer is designed with emissions testing in mind.

  • It can handle a maximum of four (350M) or six (350 XL) sensors.
  • It comes with a separate control unit housing a Peltier Chiller to remove water from the sample, and many other features. There is an electric cable between control unit and handheld, and a hose between the handheld and the probe.

http://www.powrtechsolutions.com/images/testo_2.jpg

Standard Features:
Oxygen, CO, NO and NO2 cells
CO over range protection & Purge Valve
Calculate excess air, CO2, efficiency, for 18 fuels
Differential Pressure sensor for stack flow, sample flow
Peltier Chiller, sampling pump drawing up to 80 in wc
12 in probe and 7 ft probe
Software
Carrying case, Printer
Diagnostics
Probe and Hose Options:
Standard is 12 in probe, 7 ft hose and 6 ft control cable
Options are:
          28 in probe
          16 ft hose
          16 ft control cable
          65 ft control cable
          13 in pitot tube
Cell Options:
          NO Low
          CO Low
          SO2
          CxHy
          H2S
          CO2 NDIR
Other Options:
          4 to 20 ma output
          Touch screen
          Calibration gas kits
Testo offers their 350 in affordable kit form to provide frequently requested combinations of features at very good prices.


 Feature:

#1 Boiler

#2 Standard

#3 Engine

#4 Turbine

 Oxygen 0 – 25%

X

X

X

X

 CO 0 – 10,000 ppm

X

X

X

 

 CO Low 0 – 500 ppm

 

 

 

X

 NO 0 – 3000 ppm

 

X

X

 

 NO Low 0 – 300 ppm

 

 

 

X

 NO2 0 – 500 ppm

 

X

X

X

 CO Dilution up to 40:1

 

 

X

X

 CO Over range protection

X

X

X

X

 Purge Valve for long term tests

X

X

X

X

 Differential Pressure

X

X

X

X

 Peltier Chiller

X

X

X

X

 Touch Screen

 

 

 

X

 6 ft. Control Cable

X

X

 

 

 16 ft Control Cable

 

 

X

X

 12 in probe with 7 ft hose

X

 

 

 

 12 in probe with 7 ft teflon hose

 

X

 

 

 Probe adapter with 13 in teflon hose

 

 

X

 

 12 in probe with 16 ft teflon hose

 

 

 

X

 Software

 

X

X

X

 Case

X

X

X

X

 

 

 

 

 

 Options and upgrades can be added to kits.

 

 

 

 

AddThis Social Bookmark Button

Additional information